How do you test a blower motor resistance?

Place one lead of the Ohmmeter on terminal 1 of the resistor. Place the other lead on terminal 2 and check against specifications. If this circuit is open, showing infinity on the Ohmmeter, the blower resistor must be replaced. Move the lead from terminal 2 to terminal 3 and check this reading against specifications.

How do you test a blower motor with a multimeter?

Using a multimeter set on the Ohm scale, use the positive lead and test the black wire. To check the purple wire for current, use your ignition key and turn it to the run setting, turn the heater power to full power and set the multimeter to DC power. If your meter reads “no current” the motor is no good.

How do you tell if it’s the blower motor or resistor is bad?

Symptoms of a Bad or Failing Heater Blower Motor Resistor

  1. Blower motor stuck on one speed. A common symptom of a faulty blower motor resistor is a blower motor that is stuck on one setting. …
  2. Blower motor does not work on certain settings. …
  3. No air from the vehicle’s vents.

How much resistance should a blower motor resistor have?

According to the service manual, it must be around 4-5 ohms. In our case the ohmmeter shows open circuit, which means the resistor has failed. Sometimes, a blower motor resistor might fail due to problems with the blower motor itself.

IMPORTANT:  What provides electricity to the car when it's running?

Can a blower motor resistor be tested?

If you want to do a quick test of the blower resistor, you can check the resistance of each of the resistors with a multimeter as follows: set the tool to read ohms (a measurement of resistance) and connect one of its probes to the common output terminal of the resistor.

Can a blower motor resistor be bypassed?

Blower resistors are made of several resistors with different resistances. … In the highest speed state, the blower resistor is bypassed completely and the fan is connected directly to the car’s battery, which allows maximum current through the motor.

Why does my blower motor not work on high?

In a situation where the motor doesn’t work on any speed, the most likely causes are: a blown power supply fuse, a bad motor ground connection, bad motor speed control module or a failed motor. On all systems, a failed blower motor is least likely.

What happens when blower motor relay goes bad?

If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.